Home › feature › aq130
Tunnel (AQ130)
DGIF baseline 2026-1, the latest. Earlier baselines: timemap.
RDF: aq130.ttl
- Name
Tunnel
- Kind
- FeatureType
- Definition
- An underground passage that is open at both ends and usually contains a land transportation route (for example: a road and/or a railway).
- Description
- Commonly used to pass through a hill or mountain, or under a river or road. May also provide underground passage in a mine.
- Accepted
- 2013-10-18
- Geometry
- point, curve, surface
- Subtype of
- ZI028 Feature Entity
- Attributes
- AIP Angle Of Intended Passage — multiplicity 0..1; datatype AngleMeasureMeta
- BCC Bypass Condition — multiplicity 0..1; datatype Tunnel_bypassConditionMeta; values: BCC_1 Easy, BCC_2 Difficult, BCC_3 Impossible
- CAA Controlling Authority — multiplicity 0..1; datatype Tunnel_controllingAuthorityMeta; values: CAA_17 Public, CAA_3 Private
- CAI Controlling Authority Identification — multiplicity 0..*; datatype CharacterStringMeta
- TCS Cross-sectional Profile — multiplicity 0..1; datatype Tunnel_crossSectionalProfileMeta; values: TCS_1 Arch, TCS_2 Box, TCS_3 Semicircular
- DZC Deck Count — multiplicity 0..1; datatype IntegerMeta
- DZP Deepest Depth Below Surface Level — multiplicity 0..1; datatype MeasureMeta
- COS Facility Operational Status — multiplicity 0..1; datatype Tunnel_facilityOperationalStatusMeta; values: COS_13 Operational, COS_14 Partially Operational, COS_4 Non-operational, COS_6 Planned, COS_8 Not in Operation, COS_9 Temporarily Non-operational
- HST Hazard Shelter Intended Use — multiplicity 0..*; datatype Tunnel_hazardShelterIntendedUseMeta; values: HST_1 Bomb Shelter, HST_2 Fallout Shelter, HST_3 Storm Shelter
- HGT Height Above Surface Level — multiplicity 0..1; datatype HeightMeasureMeta
- HCA Horizontal Clearance — multiplicity 0..1; datatype MeasureIntervalMeta
- LEA Least Depth Below Surface Level — multiplicity 0..1; datatype MeasureMeta
- AZC Man-made — multiplicity 0..1; datatype BooleanMeta
- MVC Maximum Vertical Clearance — multiplicity 0..1; datatype MeasureMeta
- MOS Monitored — multiplicity 0..1; datatype BooleanMeta
- OHC Overhead Clearance — multiplicity 0..1; datatype MeasureMeta
- TRA Pedestrian Traversable — multiplicity 0..1; datatype BooleanMeta
- PRM Permanent — multiplicity 0..1; datatype BooleanMeta
- PCF Physical Condition — multiplicity 0..1; datatype Tunnel_physicalConditionMeta; values: PCF_1 Construction, PCF_2 Intact, PCF_3 Unmaintained, PCF_4 Damaged, PCF_5 Dismantled, PCF_6 Destroyed
- HCC Restricted Horizontal Clearance — multiplicity 0..1; datatype BooleanMeta
- WD2 Route Total Usable Width — multiplicity 0..1; datatype MeasureIntervalMeta
- SHC Safe Horizontal Clearance — multiplicity 0..1; datatype MeasureMeta
- MCC Structural Material Type — multiplicity 0..*; datatype Tunnel_structMatTypeMeta; values: MCC_104 Soil, MCC_108 Stone, MCC_16 Clay, MCC_21 Concrete, MCC_46 Gravel, MCC_5 Asphalt, MCC_57 Macadam, MCC_62 Masonry, MCC_7 Bedrock, MCC_77 Prestressed Concrete, MCC_83 Reinforced Concrete, MCC_84 Rock, MCC_88 Sand, MCC_9 Brick
- LOC Vertical Relative Location — multiplicity 0..1; datatype Tunnel_verticalRelativeLocationMeta; values: LOC_17 On Waterbody Bottom, LOC_23 Below Waterbody Bottom, LOC_40 Below Ground Surface, LOC_46 Above Waterbody Bottom
- Associations
- Inverse associations
- RWOI terms naming it
Source: DGIF 2026-1 QEA model, DGIWG. Standard: DGIWG 206-3. Licence: CC BY 4.0, © DGIWG.